Chapter 3 : Creating a Project
Following is an example to illustrate the use of some of the options
described above.
If the request to ask your scale to send weight information has the
following structure: <STX> as a start of text character, followed by
the command SP64, and ending with a <CRLF> (Carriage Return,
Line Feed), then your Data To Send settings should look as shown
below:
If, in return, you weight scale’s return data stream starts with
<STX>, followed by the weight, and ends with a <CR>, your Data
To Receive settings should look as shown below
When the entire data stream is received from the scale, the <STX>
and <CR> are automatically stripped off—leaving only the
information you are requesting, i.e. the weight.